March
27, 1989 Service
Letter #15 SUBJECT:
Wing Tanks, WT-1R and WT-1L and Header Tank, IP-4. TO:
Kitfox™ Owners with Serial numbers #2 through #270 FROM:
Denney Aerocraft Company There
have been reported incidences of aluminum particles traveling from wing
tanks to header tanks. We now apply sloshing compound to all wing tanks
and header tanks. If in doubt you may visually inspect your tank;
sloshing compound appears as a white coating on the inside of the
aluminum tanks. IF
YOUR TANK(S) DO NOT HAVE THE COATING IT IS RECOMMENDED THAT YOU APPLY A
FUEL RESISTANT SLOSHING COMPOUND TO THEM AFTER FLUSHING THEM OUT. YOU
MAY APPLY THE SLOSHING COMPOUND TO INSTALLED WING TANKS BY REMOVING THE
WING FROM THE AIRCRAFT. |
|